| Brand Name: | QIANSU |
| Model Number: | QST-CH300E |
| MOQ: | 1 unit |
| Price: | Negotiation |
| Payment Terms: | 30% T/T deposit,70% balance before shipment |
| Supply Ability: | 30 units per month |
Inside a semiconductor or pharmaceutical cleanroom, a mobile base is judged by what it releases into the air and what it carries on its surface. This 300 kg chassis addresses both. The frame and deck are finished with a conductive coating bonded to earth through the wheel hubs, giving a controlled surface resistance that bleeds static without creating a spark path. The mecanum rollers use a carbon-loaded polyurethane compound, and the gearboxes run sealed with a low-outgassing grease rather than the mist-lubricated units common on industrial platforms.
Particle generation was treated as a design constraint from the first drawing. Cable runs are captured in closed ducts, fasteners are stainless with captured washers, and there are no exposed sliding surfaces to abrade. The deck plate is a single machined sheet rather than a welded assembly, eliminating the crevices where residue collects during wipe-down. With the standard low-shedding wheel set fitted, the platform is intended for ISO Class 7 areas and is often specified for Class 6 zones where the vehicle stays outside the critical laminar field.
Key Features| Parameter | Specification |
|---|---|
| Rated payload | 300 kg |
| Platform mass | 95 kg without battery |
| Wheel configuration | 4 x 150 mm static dissipative mecanum |
| Surface resistance | 1 x 10^6 to 1 x 10^9 ohm |
| Deck size | 800 x 600 mm machined plate |
| Travel speed | 0.8 m/s maximum |
| Frame finish | Conductive coated steel |
| Drive | Sealed brushless servo with gearbox |
| Recommended environment | ISO Class 7, option for Class 6 peripheral use |
| Grounding point | M8 stud at rear frame rail |
Wafer handling and reticle transport vehicles in semiconductor front-end areas, flat panel inspection platforms and pharmaceutical dispensing carts are the typical hosts. Electronics assembly lines that build sensitive boards also use the chassis where ordinary platforms cause intermittent ESD failures. Laboratories moving analytical instruments between benches specify it for the combination of low particle release and controlled static.
Integration NotesBond the grounding stud to the facility earth with a conductor sized for the site's static control plan, and verify surface resistance after final assembly rather than at the factory alone, since coating wear and floor finish both affect the measurement. Avoid solvent cleaners that attack the conductive coating; a neutral detergent and deionised water wipe is sufficient. If the vehicle enters a Class 6 zone, add the optional low-shedding roller set and schedule an ISO 14644 particle count as part of commissioning.
Packaging and DeliveryThe chassis is double bagged in cleanroom-compatible film and packed in a lined plywood case to keep the coating free of handling marks in transit. Conductive caps protect the wheel contact surfaces until the vehicle reaches the cleanroom airlock. A surface resistance test record, grounding diagram and cleaning procedure sheet accompany each unit, and replacement roller sets are supplied pre-cleaned and individually bagged.